From Rapid Manufacturing to Clinical Use: A Retrospective Observational Study of an Emergency Ventilator During the
Lenka Horakova1,2, Vaclav Ort1, Ladislav Bis1
1Department of Biomedical Technology, Faculty of Biomedical Engineering, https://ror.org/03kqpb082Czech Technical University in Prague, Kladno, Czech Republic.
Objective:
The COVID-19 pandemic spurred efforts to develop emergency ventilators, though few progressed beyond laboratory testing. This study evaluates CoroVent, a rapidly manufactured ventilator, during real-life deployment in critically ill COVID-19 patients amid ventilator shortages.
Methods:
This retrospective observational study included patients ventilated with emergency ventilator CoroVent. This device uses a novel and unique way of generating inspiratory flow and gas mixing using fast ON/OFF valves for air and oxygen, producing pneumatic pulses that are then smoothed into continuous flow. Clinical data were collected from 3 hospitals between October 2020 and March 2021, selected from 27 contacted, of which 23 responded and 4 reported clinical use.
Results:
Eight male patients (mean age 67 years, BMI 37.2 kg·m-2) with COVID-19 or suspected infection were ventilated with CoroVent for 31.3 (10.0-58.5) hours. The mean FiO2 was 71.4%, PEEP 10.6 cmH2O, and Vt 8.9 mL·kg-1 predicted body weight. CoroVent was used as an initial or replacement ventilator during device shortages. No major technical failures occurred.
Conclusions:
This is the first report of real-life clinical use of a rapidly manufactured emergency ventilator during the COVID-19 pandemic. The results confirm that such devices, if well-designed, can provide effective respiratory support when conventional ventilators are unavailable.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-III