Dose optimization in CBCT in dentistry: a survey among EADMFR members
S F Fakhtei1, R C Hoogeveen1, W E R Berkhout1
1Department of Oral Radiology and Digital Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and VU Amsterdam, Amsterdam 1182 DB, The Netherlands.
Objectives:
The aim of this study is to provide an overview of current cone beam CT (CBCT) practices in European dental clinics.
Methods:
From February to May 2023, 186 European EADMFR members were invited to complete an online survey. Participants were asked: (1) to provide exposure settings for 4 diagnostic scenarios; (2) if and how they adjust for age and body type; (3) whether they follow established protocols when selecting settings; and (4) if the Dose Area Product (DAP) is registered for CBCT scans.
Results:
A total of 59 (32%) eligible responses were received. There was a large variation in exposure parameters among clinicians within the same diagnostic scenario. Across scenarios, only voxel size and field of view (FOV) differed significantly (P < .05), with smaller settings being chosen for endodontic diagnostics and larger parameters for full-jaw imaging for implant planning. For young patients, most respondents reduced FOV (70%), mA (67%), and exposure time (59%). For larger patients, most increased mA (54%) and kV (52%). Written protocols were more frequently employed than manufacturer-recommended settings (75% vs 50% reported "most of the time" or "always"). More frequent usage of manufacturer-recommended settings correlated with larger FOV settings (P < .05). 90% reported registering the DAP.
Conclusions:
CBCT exposure parameter selection lacks consistency. Only FOV and voxel size were consistently adjusted for the indication. New guidelines providing guidance on the selection of CBCT settings could reduce variation between clinicians and enhance the uniformity of the quality of care.
Advances In Knowledge:
Lack of uniformity in CBCT parameter selection highlights the need for updated, indication-oriented, and patient-specific guidelines.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Dose-Response Relationship: Overview
Dosage Regimens: Designs and Approaches
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Dose-Response Relationship: Potency and Efficacy
Dosage Regimen: Multiple Oral Dosage