Related Experiment Video
Updated: Jan 16, 2026

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Compton Camera X-Ray Fluorescence Imaging Design and Image Reconstruction Algorithm Optimization
Shunmei Lu1, Kexin Peng1, Peng Feng2
1College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu 610059, China.
Abstract:
Traditional X-ray fluorescence computed tomography (XFCT) suffers from issues such as low photon collection efficiency, slow data acquisition, severe noise interference, and poor imaging quality due to the limitations of mechanical collimation. This study proposes to design an X-ray fluorescence imaging system based on bilateral Compton cameras and to develop an optimized reconstruction algorithm to achieve high-quality 2D/3D imaging of low-concentration samples (0.2% gold nanoparticles). A system equipped with bilateral Compton cameras was designed, replacing mechanical collimation with "electronic collimation". The traditional LM-MLEM algorithm was optimized through improvements in data preprocessing, system matrix construction, iterative processes, and post-processing, integrating methods such as Total Variation (TV) regularization (anisotropic TV included), filtering, wavelet-domain constraints, and isosurface rendering. Successful 2D and 3D reconstruction of 0.2% gold nanoparticles was achieved. Compared with traditional algorithms, improvements were observed in convergence, stability, speed, quality, and accuracy. The system exhibited high detection efficiency, angular resolution, and energy resolution. The Compton camera-based XFCT overcomes the limitations of traditional methods; the optimized algorithm enables low-noise imaging at ultra-low concentrations and has potential applications in early cancer diagnosis and material analysis.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography