Published on: April 29, 2014
Does Intraoral Scanning at the Subgingival Finish Line Affect the Accuracy of Interim Crowns?
Young-Tak Son1,2, Keunbada Son2, Ji-Min Lee1,2
1Department of Dental Science, Graduate School, Kyungpook National University, Daegu 41566, Republic of Korea.
None:
This in vitro study evaluated the internal surface trueness and the marginal and internal fit of interim crowns fabricated from intraoral scanner (IOS; i500, MEDIT, Seoul, Republic of Korea) data, considering variations in subgingival finish line depth and the use of gingival retraction. A right maxillary first molar was prepared using a milled ceramic abutment, with subgingival finish line depths set at 0, 0.25, 0.50, 0.75, and 1.00 mm from the gingival crest. All specimens were scanned with an IOS, both with and without gingival retraction. Interim crowns were designed from the scan data and produced via three-dimensional (3D) printing. Internal surface trueness was measured using 3D inspection software (Geomagic Control X version 2022.0.0; 3D Systems, Rock Hill, SC, USA), while marginal and internal fit were assessed with the silicone replica technique. Data were analyzed using the Mann-Whitney U test and Kruskal-Wallis H test (α = 0.05). In the absence of gingival retraction, internal surface trueness and crown fit decreased significantly with increasing finish line depth (p < 0.05). At a 1.00 mm depth without retraction, internal trueness reached 100.1 ± 44.5 µm and marginal fit was 189.1 ± 42.2 µm, both exceeding clinical thresholds. With gingival retraction, trueness and fit remained stable across all depths (p > 0.05). At 1.0 mm depth, trueness was 82.0 ± 61.8 µm and marginal fit was 95.2 ± 22.9 µm, both within clinically acceptable limits. A significant correlation was observed between marginal trueness and overall fit when retraction was not performed (p < 0.05). These results demonstrate that increasing subgingival finish line depth can significantly reduce intraoral scanning accuracy, resulting in suboptimal interim crown adaptation when gingival retraction is omitted. To achieve clinically acceptable internal trueness and marginal fit, gingival displacement with a retraction cord is recommended during intraoral scanning for subgingival prosthesis fabrication.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography