High-performance gas-phase chiral enantiomer detectors based on chiral-induced spin selectivity effect

Xiaocheng Wu1,2, Junjie Liu1,2, Fan Ni1,2

  • 1National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei, 230009, P. R. China.

Nature Communications
|September 26, 2025
PubMed
Summary

Researchers developed novel polymer-based gas detectors utilizing the chirality-induced spin selectivity (CISS) effect for portable enantiomer detection. These detectors offer high performance in distinguishing chiral molecules like limonene.

Related Concept Videos

High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
1.5K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
1.8K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.1K
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons00:58

¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons

Replacing each alpha-hydrogen in chloroethane by bromine (or a different functional group) yields a pair of enantiomers. Such protons are called prochiral or enantiotopic and are related by a mirror plane. Enantiotopic protons are chemically equivalent in an achiral environment. Because most proton NMR spectra are recorded using achiral solvents, enantiotopic hydrogens yield a single signal.
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
3.2K
Chirality at Nitrogen, Phosphorus, and Sulfur02:30

Chirality at Nitrogen, Phosphorus, and Sulfur

Chirality is most prevalent in carbon-based tetrahedral compounds, but this important facet of molecular symmetry extends to sp3-hybridized nitrogen, phosphorus and sulfur centers, including trivalent molecules with lone pairs. Here, the lone pair behaves as a functional group in addition to the other three substituents to form an analogous tetrahedral center that can be chiral.
A consequence of chirality is the need for enantiomeric resolution. While this is theoretically possible for all...
6.8K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.4K