Related Experiment Video
Updated: Jun 12, 2026

11:04
Biomolecular Detection employing the Interferometric Reflectance Imaging Sensor IRIS
Published on: May 3, 2011
15.1K
Preliminary Assessment of Bespoke ('X-tec') Silica Particles for IRS Applications
Stephania Herodotou1, Natalie Lissenden1, Kevin Skinley2
1Innovative Vector Control Consortium, Liverpool School of Tropical Medicine, Pembroke Place, Liverpool L3 5QA, UK.
Insects
|September 27, 2025
Summary
This study shows that X-tec silica particles can improve indoor residual spray (IRS) efficacy by using less insecticide. These novel silica carriers enhance mosquito pickup and insecticide bioavailability, maintaining residual activity for malaria vector control.
Area of Science:
- Entomology
- Materials Science
- Chemical Engineering
Background:
- Indoor residual spray (IRS) efficacy is influenced by substrate, insecticide concentration, and bioavailability.
- Optimizing insecticide delivery is crucial for effective malaria vector control.
Purpose of the Study:
- To investigate X-tec silica particles as a novel carrier for clothianidin insecticide in IRS formulations.
- To reduce insecticide content while maintaining or improving residual biological activity.
Main Methods:
- Bespoke silica particles (X-tec silica) were engineered with pore sizes to keep clothianidin amorphous.
- Material characterization assessed insecticide loading and physical form within silica pores.
- Bioefficacy tests were conducted against *Anopheles gambiae* s.s. Kisumu on glazed and unglazed tiles at varying application rates and time points.
Main Results:
- 100% mosquito mortality was achieved within 48 hours at 60 and 90 mg a.i./m² on both surfaces at 1 week.
- On glazed tiles, 100% mortality was observed within 48 hours even at the lowest rate (30 mg a.i./m²) after 8 months.
- Lower efficacy was noted on unglazed tiles, particularly at lower concentrations and longer durations, highlighting surface interaction importance.
Conclusions:
- X-tec silica shows potential for enhancing IRS efficacy with significantly reduced clothianidin concentrations.
- The formulation's performance is dependent on surface type, with glazed surfaces showing superior results.
- Further research is warranted to optimize X-tec silica formulations for broad application in IRS programs.