Related Experiment Video
Updated: Jan 16, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Impact of Automated Insulin Delivery Systems in Children and Adolescents with Type 1 Diabetes Previously Treated with
Bruno Bombaci1, Marco Calderone1, Alessandra Di Pisa1
1Department of Human Pathology and Developmental Age "G. Barresi", University of Messina, 98122 Messina, Italy.
Abstract:
Background and Objectives: Automated insulin delivery (AID) systems represent a major advancement in type 1 diabetes (T1D) management, particularly in pediatric populations. However, real-world evidence comparing their effectiveness to conventional multiple daily injection (MDI) therapy in youth remains limited. This study aimed to evaluate the impact of transitioning from MDI therapy to AID systems on glycemic control in children and adolescents with T1D, and to explore potential differences based on baseline HbA1c levels and device type. Materials and Methods: In this single-center, retrospective observational study, 76 children and adolescents with T1D were evaluated before and after switching from MDI to either the Medtronic MiniMed™ 780G or Tandem t:slim X2™ Control-IQ system. Glycemic control was assessed using continuous glucose monitoring (CGM)-derived metrics at three time points: the last 15 days of MDI therapy (T0), 15 days after (T1), and 6 months after (T2) AID initiation. Statistical comparisons were conducted across time points and between subgroups stratified by baseline HbA1c and AID system. Results: Significant improvements in glycemic control were observed as early as 15 days after AID initiation, with sustained benefits at 6 months. Time in range (TIR) increased from 62.0% at baseline to 76.7% at 15 days and 75.8% at 6 months, and time in tight range (TITR) from 39.8% to 53.9% at T1 and 52.1% at T2 (both p < 0.001). Improvements were more pronounced in participants with higher baseline HbA1c (+16.9% for TITR and +22.3% for TIR). No significant differences in glycemic outcomes were observed between device groups, although algorithm-driven differences in insulin delivery patterns were noted. Total daily insulin dose and BMI increased significantly over time (p < 0.001 and p = 0.008, respectively). Conclusions: AID therapy leads to rapid and sustained improvements in glycemic control among youth with T1D, particularly in those with suboptimal baseline control. These benefits highlight the clinical value of AID systems, while also emphasizing the need for monitoring potential metabolic impacts.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions