Related Experiment Video
Updated: Jan 16, 2026

Blast Quantification Using Hopkinson Pressure Bars
Published on: July 5, 2016
Research on the Blast Mitigation Performance of Polyurea-Steel Composite Plates Based on Constrained Layer Damping
Rui Zhang1,2, Qi Dong2, Zhiqiang Fang3
1Shock and Vibration of Engineering Materials and Structures Key Lab of Sichuan Province, Southwest University of Science and Technology, Mianyang 621010, China.
None:
To address the challenge of balancing the damping performance with mechanical strength in conventional polyurea materials for blast mitigation, this study develops a constrained layer damping coating structure using Q413t viscoelastic polyurea (Q413t) as the damping layer and FPU-1 flexible polyurea (FPU-1) as the constraining layer. The mechanical behaviors of both types of polyurea were characterized through tensile testing at varying loading speeds, while dynamic thermomechanical analysis was utilized to evaluate their damping properties. A 75 g TNT contact explosion test and finite element simulation were employed to explore the protective mechanism. The results show that Q413t demonstrates significant strain-rate sensitivity under intermediate-strain-rate conditions, whereas FPU-1 exhibits minimal variation in mechanical strength. Q413t demonstrates a superior damping performance over a frequency range of 0-104 Hz. FPU-1 achieved a loss factor of 0.3 when the loading frequency reached 104-105 Hz. Under the 75 g TNT contact explosion load, the configuration with a 1 mm damping layer and a 3 mm constraint layer achieved a maximum displacement reduction of 35.26%. In the constrained layer damping coating, the damping layer contributes to blast protection through energy dissipation and load distribution, while the constraining layer reduces structural deformation by limiting displacement. Relative motion between the layers further enhances the overall damping performance. The constrained layer damping coating provides optimal blast protection when the damping-to-constraining layer thickness ratio is 1:3. The constrained layer damping coating enables the synergistic optimization of mechanical strength and energy dissipation, effectively mitigating structural deformation induced by blast loading and demonstrating promising engineering application potential.
More Related Videos
10:52Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...
Fiber Reinforced Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Design Consideration
The factor of safety is another key...
Fluid Pressure over Flat Plate of Variable Width