Related Experiment Video
Updated: Jan 16, 2026

Step-by-Step Stapedotomy through Transcanal Exclusive Endoscopic Approach
Published on: March 5, 2022
Evaluating Middle Ear Absorbance and Resonant Frequency in Patulous Eustachian Tube Patients Using Wideband
Iori Kusaka1, Ryoukichi Ikeda1, Masato Suzuki1
1Department of Otolaryngology and Head and Neck Surgery, Iwate Medical University School of Medicine, Iwate, Japan.
Objective:
This study aimed to investigate the utility of wideband tympanometry (WBT) in diagnosing patulous Eustachian tube (PET) by examining differences in middle ear absorbance and resonant frequency between PET patients and controls.
Study Design:
This is a retrospective observational study.
Setting:
This study was conducted at Iwate Medical University Hospital.
Subjects And Methods:
A review of medical records identified 25 ears of 19 PET patients and 18 ears of 9 patients with sensorineural hearing loss or vertigo as a control group. Diagnosis of PET was based on Japan Otological Society criteria. WBT was conducted across frequencies of 226-8000 Hz, measuring ambient pressure absorbance ratios and peak pressure absorbance ratios, as well as resonant frequency (RF) values.
Results:
The PET group demonstrated significantly lower absorbance at 1000 Hz (P = 0.006) compared with the control group, with no significant differences observed at other frequencies. The RF was significantly reduced in the PET group compared with controls (P < 0.001), indicating alterations in middle ear mechanics associated with PET. The Valsalva maneuver had no significant effect on absorbance values across frequencies.
Conclusion:
WBT is a valuable diagnostic tool for PET, with significant reductions in 1000 Hz absorbance and resonant frequency in PET patients. These parameters may serve as markers for PET, aiding in its differentiation from other middle ear conditions.
Related Concept Videos
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Anatomy of the Ear
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:

