Related Experiment Video
Updated: May 5, 2026

Disposable Dosators for Pulmonary Insufflation of Therapeutic Agents to Small Animals
Published on: March 30, 2017
Development of Exclusive and Efficient Intranasal or Pulmonary Dosing Methods for a Dry Powder Tuberculosis Vaccine
John Z Chen1, Scott Tavernini2, Maximilian Aisenstat2
1Access to Advanced Health Institute, Seattle, Washington, USA.
Background:
In spite of efforts to eradicate tuberculosis (TB), TB remains the deadliest infectious disease in the world; there is an urgent need for a thermostable, noninvasive TB vaccine suitable for distribution in the developing world. Spray-dried versions of a clinical-stage TB vaccine, ID93 + GLA-SE, are currently undergoing testing in baboons in both pulmonary and intranasal versions. We developed manufacturing processes and delivery systems to achieve delivery of each version to its intended site of action while avoiding off-target deposition.
Methods:
Pulmonary ID93 + GLA-SE was manufactured in a custom research-scale spray dryer. Delivery efficiency using a custom intratracheal insufflator was measured gravimetrically, and aerodynamic performance was evaluated via cascade impaction. Intranasal ID93 + GLA-SE was manufactured in a pilot-scale spray dryer. In vitro regional deposition in the Alberta Idealized Nasal Inlet, measured by LC-MS/MS, was used as a surrogate for aerodynamic performance; total deposition was used to calculate a total delivered dose. For both powders, ID93 antigen content was assessed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis, and GLA-SE adjuvant content was assessed via HPLC.
Results:
No substantial processing losses of the antigen or adjuvant were observed after spray drying in either formulation. For the pulmonary powder, the emitted dose exiting the endotracheal tube across three tube sizes ranged from 15.9% to 21.4% of the nominal dose; for the 8 mm tube size, the emitted dose mass median aerodynamic diameter was 5.3 µm, which was deemed suitable for pulmonary administration. For the intranasal powder, the delivered dose was 88% ± 2% of nominal, and in vitro deposition in the posterior nasal cavity was 63% ± 10% of the emitted dose, with minimal anticipated lung deposition.
Conclusions:
Pulmonary and intranasal spray-dried ID93 + GLA-SE powders were successfully manufactured. The proposed dosing systems are expected to achieve exclusive pulmonary or intranasal delivery to nonhuman primates while requiring only a moderate amount of powder.