Related Experiment Video
Updated: May 3, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Optimisation of Margin Adaptation for Respiratory Motion in Lung Cancer Stereotactic Body Radiation Therapy Using
D Kawahara1, H Masuda2, T Wada2
1Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.
Aim:
This study applies a previously developed four-dimensional (4D) dose calculation method using virtual four-dimensional computed tomography (v4DCT) to evaluate and optimise the use of an optimal margin (OM) in lung stereotactic body radiation therapy (SBRT). Specifically, we assess the clinical feasibility of an OM derived from different prescription isodose levels and its impact on target coverage and normal tissue sparing.
Materials And Methods:
Volumetric modulated arc therapy (VMAT) plans were created using a whole-body phantom with a virtual lung tumour. Treatment planning ensured that 95% of the planning target volume (PTV) was covered by the prescription isodose lines for 70%, 75%, and 80%. v4DCT images were generated assuming free breathing. The four-dimensional radiotherapy (v4DRT) dose represented the accumulated dose across all respiratory phases. The dosimetric internal margin (DIM) was defined as the maximum amplitude ensuring D100% and D99% coverage of the gross tumour volume (GTV). The OM was determined based on the average dose to the GTV and the dose to organs at risk (OARs) for the 70% to 80% isodose plans.
Results:
The DIM was determined to be 2.0 to 2.6 times larger than the conventional margin accounting for respiratory motion. Implementation of the optimised margin resulted in a significant reduction of the V20Gy for normal lung tissue under respiratory motion conditions. Additionally, the maximum dose at distances of 0.5 to 2.0 cm from the PTV showed a reduction with larger amplitudes. The OM with 70% and 75% isodose plan achieved a 55% to 62% reduction compared to the conventional PTV margin with 80% isodose plan.
Conclusion:
This study proposes an OM for lung SBRT with marginal prescription. This approach reduced the respiratory motion margin by 55% to 62% while maintaining target dose coverage and lowering OAR exposure.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...