Preventing volume loss during extubation in preterm infants: a prospective observational study
Leonie Plastina1, Kaylen Gähwiler2, Vincent D Gaertner3,4
1Department of Neonatology, Newborn Research Zurich, University Hospital Zurich, Frauenklinikstrasse 10, Zurich, 8091, Switzerland. leonie.plastina@usz.ch.
Background:
To evaluate changes in end-expiratory lung impedance (EELI), a surrogate for end-expiratory lung volume (EELV), during a minimal-handling extubation protocol in very preterm infants in prone position. The protocol aimed to minimize interruptions in positive end-expiratory pressure (PEEP) delivery.
Methods:
This was a prospective observational study including preterm infants born before 32 weeks' gestation who underwent elective extubation without conditions negatively impacting lung aeration or perfusion. Participants were recruited at the University Hospital Zurich (June 2023-March 2024). We compared a novel extubation protocol that minimizes infant handling to a conventional protocol. Lung volume changes were continuously monitored noninvasively via electrical impedance tomography (EIT), capturing end-expiratory lung impedance (EELI) as a proxy for end-expiratory lung volume (EELV). The pulse rate (PR), oxygen saturation (SpO2), and inspired oxygen fraction (FiO2) were recorded continuously. Changes in EELI and cardiorespiratory parameters were compared to those at baseline (before the infant was first handled).
Results:
Fifteen extubations were analysed. At initiation of non-invasive ventilation (NIV), the median EELI decreased by -0.68 AU/kg (IQR: -0.99 to -0.21), reflecting a median EELV loss of 27.7 ml/kg (IQR: -40.6 to -8.6). The greatest EELI loss occurred during tape removal (-0.24 AU/kg, padj = 0.025), whereas the greatest recovery occurred during stabilization (0.31 AU/kg, padj = 0.025). The duration of extubation was 1.7 min (IQR: 1.3-2.0), with a 2-second median interval (IQR: 1-4) between tube removal and NIV. Oxygen saturation remained stable (padj = 0.32).
Conclusions:
While minimal handling did not prevent lung volume loss during extubation, a stabilization period preceding extubation facilitated partial lung volume restoration.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Suctioning II: Procedure
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...