High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
Impact of embedded 163 Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment
Douglas Bennett1, Matteo Borghesi2,3, Pietro Campana2,3
1National Institute of Standards and Technology (NIST), Boulder, CO USA.
Abstract:
We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of Ho to be J/K/mol at mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate Ho activities up to approximately 5 Bq, with only about a factor of three degradation in performance compared to detectors without Ho. For higher activities, reducing the TES transition temperature is necessary to maintain or improve the energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling limited amounts of implanted radionuclides while maintaining high-resolution performance.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
Related Concept Videos
Calorimetry
Constant Pressure Calorimetry
Constant Volume Calorimetry
Photoelectric Effect
Voltammetry: Factors Affecting Measurements
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...