Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Validity of Heart Rate Measurement Using Wearable Devices During Cardiopulmonary Exercise Testing in Patients With
Kazufumi Kitagaki1,2, Yuji Hongo2, Rie Futai3
1Faculty of Rehabilitation, Shijonawate Gakuen University, 5-11-10 Houjou Daito, Osaka, 574-0011, Japan, 81 72-863-5043, 81 72-863-5022.
Background:
Wearable devices offer a promising solution for remotely monitoring heart rate (HR) during home-based cardiac rehabilitation. However, evidence regarding their accuracy across varying exercise intensities and patient profiles remains limited, particularly in populations with cardiovascular disease (CVD) such as those with heart failure (HF).
Objective:
The objective of this study was to evaluate the accuracy of HR measurements obtained using the Fitbit Inspire 3 during cardiopulmonary exercise testing (CPX) in patients with CVD, including those with HF.
Methods:
In this single-center, prospective pilot study, we enrolled 30 patients with CVD undergoing CPX. HR was simultaneously recorded using electrocardiography and the Fitbit Inspire 3 at 1-minute intervals across various CPX phases: rest, exercise below and above the anaerobic threshold (AT), and recovery. The correlation between the two methods was assessed using the Pearson correlation coefficient. Measurement error was quantified by mean absolute error and mean absolute percentage error (MAPE), with a MAPE of ≤10% defined as the threshold for acceptable agreement.
Results:
All data points were 630 points per minute. The Fitbit Inspire 3 device demonstrated a strong overall correlation with electrocardiography-derived HR (r=0.90; IQR 0.88-0.91) and an acceptable MAPE of 5.40% (SD 8.33%). The total error was 14.9% (94/630), with overestimation and underestimation of 37 (5.8%) points and 57 (9%) points, respectively. The rate of HR underestimation reached 19 (16%) points during exercise above the AT, compared to 1 (3%) point at rest. When stratified by HF stage (B vs C), underestimation was more pronounced in patients with HF (14/275, 5% points vs 40/355, 11.2% points).
Conclusions:
The Fitbit Inspire 3 provides acceptable validity for HR monitoring during CPX in patients with CVD. However, clinicians should interpret HR data with caution during high-intensity exercise, especially in patients with HF.
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Holter Monitor: 24-Hour Monitoring
Pulse
The pulse serves as a clinical...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...