Usefulness of Automated Analysis System for Microvascular Blood Flow Rate Using Magnifying Endoscopy in Early Gastric
Yoichi Akazawa1, Hiroya Ueyama1, Shunsuke Nakamura1
1Department of Gastroenterology, Juntendo University School of Medicine, Tokyo, Japan.
Journal of Gastroenterology and Hepatology
|October 7, 2025
Summary
A new automated system for analyzing microvascular blood flow rate aids in early gastric cancer (EGC) diagnosis. This tool shows diagnostic performance comparable to or better than skilled endoscopists, improving EGC differentiation from patchy redness (PR).
Area of Science:
- Gastroenterology
- Medical Imaging
- Artificial Intelligence in Medicine
Background:
- Differentiating early gastric cancer (EGC) from patchy redness (PR) after Helicobacter pylori eradication is challenging.
- Magnifying endoscopy is crucial for EGC diagnosis, but interpretation can be difficult.
- Automated analysis of microvascular blood flow offers a potential solution.
Purpose of the Study:
- To develop and evaluate a novel automated analysis system for microvascular blood flow rate using magnifying endoscopy.
- To compare the diagnostic performance of this system against experienced endoscopists in differentiating EGC from PR.
- To assess the system's utility as a new diagnostic tool in clinical practice.
Main Methods:
- Analysis of 76 magnifying endoscopy videos (36 EGC, 40 PR).
- Development of an automated system to diagnose lesions based on microvascular blood flow rate.
- Comparison of the system's diagnostic accuracy, sensitivity, and specificity with 30 endoscopists (15 experts, 15 trainees).
Main Results:
- The automated system achieved diagnostic accuracy of 84.2%, sensitivity of 86.1%, and specificity of 82.5%.
- Endoscopists achieved diagnostic accuracy of 84.2%, sensitivity of 80.2%, and specificity of 87.3%.
- The system's sensitivity and negative predictive value were higher than those of endoscopists, with accuracy comparable to all endoscopists and superior to trainees.
Conclusions:
- The automated microvascular blood flow analysis system demonstrates diagnostic performance equivalent to or superior to skilled endoscopists.
- This system shows promise as a valuable new tool for differentiating early gastric cancer from patchy redness.
- Further clinical implementation of this automated system could enhance EGC diagnosis.