Related Experiment Video
Updated: Jan 15, 2026

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
False Positive Findings of 68Ga-DOTATOC PET/CT: A Systematic Review
Dhuha Al-Adhami1, Ahmed Saad Abdlkadir1, Sze Ting Lee2
1King Hussein Cancer Center (KHCC), Clinic of Nuclear Medicine and PET/CT, Amman, Jordan.
False positive findings with Gallium-68 DOTATOC scans are common, particularly in the abdomen and head/neck. Understanding these pitfalls improves diagnosis and may reveal new uses for this imaging agent.
Area of Science:
- Nuclear Medicine
- Radiopharmaceuticals
- Diagnostic Imaging
Background:
- Gallium-68 DOTATOC (68Ga-DOTATOC) is widely used for diagnosing neuroendocrine tumors (NETs).
- False positive findings can lead to misdiagnosis and unnecessary interventions.
- Systematic review of reported false positive findings is needed to improve diagnostic accuracy.
Purpose of the Study:
- To systematically review and categorize reported false positive findings of 68Ga-DOTATOC.
- To identify common sites and etiologies of these false positive results.
- To enhance the understanding and clinical application of 68Ga-DOTATOC.
Main Methods:
- Systematic search of PubMed, Web of Science, and Scopus databases updated until March 4, 2024.
- Independent screening of titles and abstracts by three authors based on inclusion/exclusion criteria.
- Qualitative analysis of 42 included articles involving 601 patients.
Main Results:
- A total of 219 false positive findings were identified and categorized.
- Non-oncologic etiologies (50.2%) predominated, followed by benign (27.4%) and malignant neoplasms (22.4%).
- Abdomen (30.6%) and head/neck (20.5%) were the most common sites for false positives, often related to meningiomas and NETs.
Conclusions:
- False positive findings in 68Ga-DOTATOC imaging are frequent and diverse.
- Understanding these pitfalls is crucial for accurate diagnosis and patient management.
- Recognizing false positives may expand the utility of 68Ga-DOTATOC beyond NETs and meningiomas.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
10:47Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET