Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
KURAMA vs. Safecast: Radiation data comparison in Fukushima following whole-area decontamination
Imam Ghazali Yasmint1, Yo Ishigaki2, Kayoko Yamamoto2
1Joint Doctoral Program for Sustainability Research, University of Electro-communications, Tokyo, Japan.
Abstract:
Following the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in 2011, environmental radiation monitoring is crucial for supporting reconstruction programs and ensuring the safety of returning residents. Although government-led monitoring systems yield relatively accurate data, limited coverage exists in some areas. Consequently, citizen-science initiatives, such as Safecast, emerged to address these gaps. We compare two major radiation monitoring systems in Fukushima Prefecture over the period 2019-2023: the Kyoto University Radiation Mapping (KURAMA) system and Safecast. As measurements are not co-located, all readings were aggregated onto a uniform 100 × 100 m grid for spatial comparison. At the current low ambient-dose levels, a nearly constant contribution from secondary cosmic radiation can measurably inflate readings from Geiger-Müller (GM) detectors. The analysis examines spatial coverage, radiation dose rate distribution, and data fitting through linear regression, error analysis, and Bland-Altman analysis. The results show that KURAMA provides extensive area coverage (1068-1419 km2 per year) with sharp radiation dose transitions, particularly in high-exposure areas. In contrast, Safecast encompasses approximately 10 % of the area surveyed annually by KURAMA. We found that some Safecast areas cover residential areas and public facilities not monitored by KURAMA. Regression analysis indicates a strong linear correlation (R2 = 0.8034). It also reveals a systematic bias in uncorrected Safecast data, yielding higher doses in low-exposure areas (<0.5 μSv/h) and lower doses in high-exposure areas (>1.0 μSv/h) compared to KURAMA. A key driver of the low-dose overestimation is the 31 nSv/h contribution of secondary cosmic radiation inherently counted by Safecast's GM detector. Subtracting this constant background (yielding Safecast_CR) lowers the Safecast median from 0.127 to 0.096 μSv/h and improves low-dose agreement with KURAMA while not changing the R2 value. This claim of systematic bias is further strengthened by additional statistical analysis showing a consistent pattern of measurement discrepancies. These differences are influenced by detector characteristics, data collection methods, and operational variability, including the cosmic-ray component. Our findings indicate that integrating both systems, with appropriate calibration of Safecast data, can enhance the accuracy of radiation exposure assessments, improve post-decontamination monitoring, and contribute to more representative radiation maps for public safety and policy-making.
More Related Videos
07:08Establishment of a Robust and Reproducible Model of Radiation-Induced Skin and Muscle Fibrosis
Published on: August 31, 2022
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
Related Concept Videos
Radiation: Applications
The average...
Biological Effects of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...