Carbon Black and PEDOT:PSS in a Synergistic Solid Contact for Reliable Printed Potentiometric Sensors
Christian Gosti1, Zekra Mousavi2, Luca Fiore1,3
1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via Della Ricerca Scientifica 1, 00133 Rome, Italy.
Abstract:
Printed potentiometric sensors require reliable solid contacts to provide stable and reproducible ion-selective electrodes. However, hampering fabrications and unfavorable maintenance often hinder their breakthrough on a commercial scale. Herein, we develop a solid-contact calcium-selective screen-printed electrode harnessing straightforward manufacturing based on the combination of carbon black (CB) and poly(3,4-ethylene dioxythiophene) doped with poly(sodium 4-styrenesulfonate) (PEDOT:PSS) as an ion-to-electron transducer. Drop-casting was used to simply deposit the CB layer, while PEDOT:PSS was rapidly electropolymerized (71 s) onto the working electrode to deliver affordable manufacturing of the printed electrode while ensuring valid potentiometric performance. Subsequently, the ion-selective membrane (ISM) and the polyvinyl butyral (PVB)-based reference membrane were, respectively, drop-cast onto the working electrode and reference electrode (RE). Upon the optimization of solid-contact layers, the solid-contact Ca2+-ISEs were investigated by evaluating their potentiometric performance versus a conventional RE. CB/PEDOT:PSS-modified screen-printed electrodes demonstrated a low-frequency capacitance of 55 μF, and an outstanding standard potential interelectrode reproducibility (±1 mV). The combination of both types of ion-to-electron transducers provided calcium detection in the linear range 10-1-10-7 M with a Nernstian sensitivity (28.3 ± 0.3 mV/decade), ensured over 28 days under dry storage. Furthermore, the absence of the water layer effect was also demonstrated. Lastly, the fully printed platform was assembled to achieve a miniaturized and easily field-deployable potentiometric device, consisting of CB/PEDOT:PSS/ISM configuration and PVB-based reference membrane on the working electrode and the RE, respectively. The resulted all-solid-state sensor revealed a Nernstian sensitivity with a 29.0 ± 0.5 mV/decade slope and a stable signal up to 72 h (drift = -0.2 mV/h). Analysis carried out using commercially available bottled water also demonstrated the sensor successful performance in the determination of calcium ion in real samples.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Overview