Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Effective point of measurement calculations for cylindrical ionization chambers in kilovoltage x-ray beams
Wei Tan1, Brendan James Healy2, Robin Hill1,3
1Institute of Medical Physics, School of Physics, The University of Sydney, NSW 2006, Australia.
Abstract:
Objective.Knowledge of the effective point of measurement (EPOM) of ionization chambers is needed in relative dosimetry for kilovoltage x-ray beams. This study used Monte Carlo calculations to determine EPOM of three cylindrical ionization chambers in kilovoltage x-ray beams.Approach.The EGSnrc Monte Carlo code was used for all calculations for central axis depth doses in a water phantom and in the air cavity of cylindrical ionization chambers in water. EPOM shifts were calculated for x-ray beams from 50 kVp to 300 kVp with half value layer (HVL) from 0.07 to 3.5 mm Cu, with field sizes from 5 to 15 cm diameter. Three cylindrical ionization chambers (NE 2571, Exradin A12 and PTW 30013) were realistically modelled in EGSnrc. The EPOM shift value was identified from the minimum deviation in the ratio of the dose-to-water and the dose-to-air in the chamber cavity, following published numerical methods.Main Results.EPOM shifts normalized to the radius (r) of the cylindrical chamber of the air cavity were calculated to be within 0.2 r of the central axis for HVLs between 0.5 and 3.5 mm Cu. For HVLs less than 0.5 mm Cu, the EPOM shift increased with decreasing HVL. The EPOM shift did not change significantly with field size. Once the EPOM shift is applied, residual differences between the dose-to-water depth curves and dose-to-air cavity depth curves were found to be less than 0.5% in most cases.Significance.Monte Carlo calculations confirm a zero EPOM shift for cylindrical ionization chambers in x-ray beams with HVLs greater than 0.5 mm Cu. The calculated EPOM shifts begin to deviate significantly from zero for HVLs less than 0.5 mm Cu. Current recommendations of a uniform zero EPOM shift for cylindrical ionization chambers in kilovoltage x-ray beams may be inadequate for accurate relative dosimetry in the entire medium-energy x-ray range.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Mass Analyzers: Common Types
Biological Effects of Radiation
Calculations of Electric Potential I
The ring is divided into infinitesimal small arcs such that point M is equidistant from all the arcs. Here, the cylindrical coordinate system is used to calculate the electric potential at point M. A general element of the arc between angles θ and θ + dθ is of the length Rdθ and has a charge of...
Calculations of Electric Potential II
Consider a...
Finding Electric Potential From Electric Field
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview