Related Experiment Video
Updated: Jan 15, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Diffusion-Weighted Magnetic Resonance Imaging in Suspicious Breast Lesions Detected on Ultrasonography and
Amrita Das1, Sujan Dibragede2, Sukanya Goswami3
1Department of Radiodiagnosis, Tezpur Medical College and Hospital, Tezpur, IND.
Abstract:
Introduction Diffusion-weighted magnetic resonance imaging (DW-MRI), an advanced functional imaging method, offers a notable advantage over traditional dynamic contrast-enhanced MRI (DCE-MRI) by generating tissue contrast without requiring the injection of intravenous contrast agents. The aim of the study is to evaluate the role of DW-MRI in suspicious breast lesions encountered primarily on ultrasonographic and mammographic evaluation. Methods A hospital-based cross-sectional study was performed between July 2023 and December 2023, including 34 suspicious breast lesions in 32 females detected on ultrasonography and mammography. Cases underwent MRI on a 1.5 Tesla scanner using a dedicated breast coil. DW MRI was done with b-values of 500, 800, and 1000 s/mm². Lesions were characterized by ultrasonography and mammography as per the ACR BI-RADS lexicon. Histopathological diagnosis was considered the gold standard of reference. Results Of 34 breast lesions, 16 (47.1%) were benign and 18 (52.9%) were malignant. The cut-off ADC value derived by the receiver operating characteristic (ROC) curve was 1.12 x10-3 mm²/s using different b values of 500, 800, and 1000 s/mm², which yielded optimal sensitivity (88.6%) and specificity (78.6%). The mean apparent diffusion coefficient (ADC) values of benign and malignant lesions were 1.51±0.22 x10-3 mm²/s and 1.0±0.09x10-3 mm²/s, respectively (p<0.0001). The mean ADC value of normal breast parenchyma was 1.68 ± 0.02 x 10-3 mm²/s (p<0.0001). DW‑MRI achieved a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DW-MRI by using ADC mapping that were found to be 88.6%, 78.6%, 83.8%, 84.6%, and 84.1%, respectively, in this study. Conclusion DW-MRI can be a potential adjunct to routine screening and diagnostic modalities and can be used as a problem-solving tool in suspicious breast lesions encountered on conventional imaging.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies II: Ultrasonography
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

