Related Experiment Video
Updated: Jan 15, 2026

Research and Development of High-performance Explosives
Published on: February 20, 2016
Field Explosives Detectors-Current Status and Development Prospects
Dariusz Augustyniak1, Mateusz Szala1
1Faculty of New Technologies and Chemistry, Department of Explosives, Military University of Technology, S. Kaliskiego 2, 00-908 Warsaw, Poland.
Abstract:
This review critically evaluates the performance of approximately 80 commercially available mobile detectors for explosive identification. The majority of devices utilize Ion Mobility Spectrometry (IMS), Fourier Transform Infrared Spectroscopy (FTIR), or Raman Spectroscopy (RS). IMS-based instruments, such as the M-ION (Inward Detection), typically achieve sensitivities at the ppt level, while other IMS implementations demonstrate detection ranges from low ppb to ppm. Gas Chromatography-Mass Spectrometry (GC-MS) systems, represented by the Griffin™ G510 (Teledyne FLIR Detection), provide detection limits in the ppb range. Transportable Mass Spectrometers (Bay Spec) operate at ppb to ppt levels, whereas Laser-Induced Fluorescence (LIF) devices, such as the Fido X4 (Teledyne FLIR Detection), achieve detection at the nanogram level. Quartz Crystal Microbalance (QCM) sensors, exemplified by the EXPLOSCAN (MS Technologies Inc. 8609 Westwood Center Drive Suite 110, Tysons Corner, VA, USA), typically reach the ppb range. Only four devices employ two orthogonal analytical techniques, enhancing detection reliability and reducing false alarms. Traditional colorimetric tests based on reagent-analyte reactions remain in use, demonstrating the continued relevance of simple yet effective methods. By analyzing the capabilities, limitations, and technological trends of current detection systems, this study underscores the importance of multi-technique approaches to improve accuracy, efficiency, and operational effectiveness in real-world applications. The findings provide guidance for the development and selection of mobile detection technologies for security, defense, and emergency response.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Electronic Distance Measuring Instruments
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Overview

