Related Experiment Video
Updated: Jan 15, 2026

Monitoring PD-1-Blocking Antibodies Bound to T Cells Derived from a Drop of Peripheral Blood
Published on: February 5, 2020
Transparency and Reporting in the Evaluation of PD1 by Flow Cytometry
Marc Sorigue1, Roser Salvia1, Jordi Petriz1
1Functional Cytomics Lab, Germans Trias i Pujol Research Institute (IGTP), Autonomous University of Barcelona (UAB), Badalona, Spain.
Reporting standards for flow cytometry in cancer research, especially for PD1 biomarker analysis, are suboptimal. Key data like gating strategies and dotplots are often missing, hindering reproducibility.
Area of Science:
- Biomedical research
- Immunology
- Oncology
Background:
- Flow cytometry is crucial for cancer research, particularly for evaluating biomarkers such as PD1.
- Transparent and reproducible reporting is essential for the validity of flow cytometry studies.
- Inadequate reporting in flow cytometry manuscripts remains a persistent issue.
Purpose of the Study:
- To assess the quality of reporting in flow cytometry studies evaluating PD1 expression in cancer research.
- To identify specific domains where reporting standards are lacking.
- To determine factors influencing reporting quality.
Main Methods:
- A methodological review of 100 recent cancer research manuscripts utilizing flow cytometry for PD1 assessment.
- Evaluation of reporting across six domains: methods, dotplot availability, gating strategy, analysis robustness, figure presentation, and data availability.
- Analysis of the correlation between reporting quality and journal impact factor or journal focus.
Main Results:
- Compliance with basic reporting standards was suboptimal, ranging from 35% to 70% across evaluated domains.
- Reporting of reagents and devices was strong (~90%), but transparency of key data (PD1 dotplots, gating sequences) was insufficient.
- Journal impact factor and specialization did not consistently correlate with higher reporting quality.
Conclusions:
- There is an urgent need to enhance reporting practices in flow cytometry research for cancer biomarkers like PD1.
- Authors, reviewers, and journal editors must collaborate to enforce minimal reporting standards for improved transparency and reproducibility.
- Addressing these reporting gaps is critical for advancing cancer research and reliable biomarker evaluation.
More Related Videos
10:18Author Spotlight: Magnetic Fluorescent Bead-Based Dual-Reporter Flow Analysis of PDL1-Vaxx Peptide Vaccine-Induced Antibody Blockade of the PD-1/PD-L1 Interaction
Published on: July 7, 2023
09:32Multiplexed Immunofluorescence Analysis and Quantification of Intratumoral PD-1+ Tim-3+ CD8+ T Cells
Published on: February 8, 2018