Related Experiment Video
Updated: Jan 14, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
coPERCIST: AI-assisted PET-CT response assessment
Elin Trägårdh1,2, Måns Larsson3, Olof Enqvist3,4
1Department of Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Inga Marie Nilssons G 49, 205 02, Malmö, Sweden. Elin.tragardh@med.lu.se.
Purpose:
The PET Response Criteria in Solid Tumours (PERCIST) 1.0 provides a standardized framework for evaluating treatment response using [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography - computed tomography (PET-CT), but its clinical use is hindered by manual complexity. This study presents coPERCIST, an artificial intelligence (AI)-assisted module integrated into the RECOMIA platform that semi-automates and streamlines PERCIST analysis.
Methods:
coPERCIST performs organ segmentation and automates key steps of the PERCIST workflow, including background activity quantification, lesion detection, SULpeak calculation, and longitudinal lesion comparison. A novel image alignment method using organ-specific transformations and uncertainty estimation enables accurate lesion tracking over time. The system was evaluated in 58 oncological patients, each with two PET-CT scans. Up to three measurable lesions per patient were analysed.
Results:
The AI-suggested liver and aorta volume of interest for threshold calculation were correct in all baseline and follow-up studies. Follow-up studies were classified as progressive metabolic disease (PMD) in 38 cases, stable metabolic disease (SMD) in 16, and partial metabolic response (PMR) in 4. Of 130 lesions evaluated, anatomical alignment was accurate in all cases, and pairwise SULpeak quantification was accurate in 95%. Pairwise SULpeak quantification failed in seven lesion pairs due to proximity to other lesions or misclassified physiological uptake. Review time was less than one minute for most cases.
Conclusion:
This study demonstrates the feasibility of AI-assisted PERCIST evaluation for [18F]FDG PET-CT, showing promising accuracy. coPERCIST offers potential for reproducible response assessment and supports future multicentre validation. It is freely available to researchers via the RECOMIA platform.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
![PET/CT With [68Ga]-NOTA-FAP-2286 for Imaging of Tendon Injuries in Rat Achilles Tendon Injury Models](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F67717.jpg&w=3840&q=50)
