Related Experiment Video
Updated: Jan 14, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Bioanalytical Uncertainty Assessment of Ultra-High-Performance Liquid Chromatography-High Resolution Mass
Wafaa El-Ghaly1, Taha El Kamli2, Lamia Zaari Lambarki3
1Drug Sciences Research Laboratory, Faculty of Pharmacy, Mohammed VI University of Sciences and Health (UM6SS), Casablanca, Morocco.
Abstract:
The quality of quantitative results in bioanalysis requires not only a validated analytical method but also a rigorous estimation of measurement uncertainty. This study examines the challenges associated with the implementation of two distinct approaches in equine anti-doping control for the assessment of uncertainty associated with an ultra-high-performance liquid chromatography-high resolution mass spectrometry quantitative method for caffeine and lidocaine in horse urine. The bottom-up approach, based on the ISO Guide to the Expression of Uncertainty in Measurement (ISO GUM), was compared to the top-down approach using β-content, γ-confidence tolerance intervals (β,γ-CCTI) via F-test. The key limitation of the ISO GUM method was accurately quantifying the various uncertainty components; it gives standardized uncertainty estimates but requires detailed assumptions and modeling about error sources. The direct application of the GUM method imposes the beforehand correction of the matrix effect to provide reliable results. Parallelly, the chemometric approach β,γ-CCTI offers more flexible and realistic estimations. Four combinations of β and γ were investigated to assess their influence on uncertainty interval width: β = 66.7% and 80%; γ = 90% and 95%; and the method was evaluated under repeatability and intermediate precision conditions through the use of advanced computation that adjusts for matrix effects and proves more straightforward for capturing variability inherent in experimental data. The top-down approach is a reliable alternative for routine use and, particularly, for ensuring compliance with regulatory requirements, with the fact that a known proportion β of future results will be within predefined acceptance limits.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018