Volume targeted mask ventilation during simulated neonatal resuscitation - A randomized crossover manikin study
Chelsea Morin1,2, Kashmala Yousafzai1, Brenda Hiu Yan Law1,2
1Centre for the Studies of Asphyxia and Resuscitation, Neonatal Research Unit, Royal Alexandra Hospital, Edmonton, Alberta, Canada.
Objective:
To compare mask positive pressure ventilation (PPV) provided by pressure guided devices (i.e., T-Piece) with or without a respiratory function monitor (RFM) with ventilator-based volume-targeted ventilation (VTV) using a VN500 Draeger ventilator or the NextStepTM, a novel ventilation device designed for the delivery room.
Methods:
Prospective, randomized, crossover, simulation study. Following orientation to ventilation devices, participants were randomized to order of four ventilation devices (NextStepTM, VN500 Draeger ventilator, T-piece PPV with RFM visible, and T-piece PPV with RFM masked) and order of four simulation scenarios. The study was performed in a neonatal resuscitation room within a level 3 neonatal intensive care unit. Participants were trained neonatal resuscitation providers or instructors with experience as team leader. Semi-automated, ventilator-based volume-targeted mask PPV (VTV-PPV) (NextStepTM or Draeger Ventilator) was compared to manual PPV via a T-piece device (RFM either visible or masked). Primary outcome was reduction in mask leak with the NextStepTM compared to the other devices.
Results:
Thirty-two healthcare professionals [25 (78.1 %) were female and 7 (21.9 %) were male] participated. The median (interquartile range) mask leak was significantly lower with VTV-PPV with NextStepTM [6 (1-12) %] compared to the Draeger Ventilator [24 (25-38)%, p = 0.01], T-Piece with RFM [18 (9-33) %, p = 0.0088], and T-Piece without RFM [32 (12-57)%, p = >0.0001]. The median (IQR) delivered tidal volume was not different between groups, although the NextStepTM had less tidal volume variation compared to all other groups and peak inflation pressure was significantly lower with VTV-PPV with NextStepTM compared to all other groups.
Conclusion:
In a neonatal manikin model, VTV-PPV with the NextStepTM using a two-hand hold reduced mask leak compared to the T-piece without RFM guidance.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...