Related Experiment Video
Updated: Jan 14, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Effect of materials with different permittivity on the sensing depth of open-ended coaxial probes at different
Guifeng Yang1, Shaohua Zhou2, Jinkang Xiao3
1School of Automation, Northwestern Polytechnical University, Xi'an 710129, China.
Abstract:
At present, there is a lack of accurate analysis of the effect of frequency on probe depth of sensing, and studies of the relationship between probe depth of sensing and frequency have focused mainly on the frequency range below 20 GHz. First, in this paper, the relationship between frequency and probe sensing depth within the 0.5-20 GHz range is experimentally analyzed. Using spatial interpolation techniques, frequency extrapolation is performed based on experimental data to derive the sensing depths of open-ended coaxial probes for materials with permittivity ranging from 2 to 80 across an extended frequency spectrum of 0.1-40 GHz. Second, we developed the first computational model of the probe sensing depth based on the exponential function using the least squares method according to the obtained data. Finally, we selected typical materials to experimentally validate the resulting computational model of sensing depth. The research results in this paper provide a method for the accurate calculation of probe sensing depth in a wide frequency range, and a theoretical reference for sample preparation based on the open-ended coaxial probe method as well as for the accurate measurement of the complex permittivity of materials.
More Related Videos
Related Concept Videos
Susceptibility, Permittivity and Dielectric Constant
Electromagnetic Waves in Matter
Consider the electromagnetic wave passing through a dielectric medium. In such a case, Maxwell's equations get modified. In Ampere's law, ε0 , the dielectric permittivity of free space is replaced with ε, the permittivity of dielectric. Also, the vacuum permeability μ0 is replaced by the permeability of the medium, μ.
Furthermore,...
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
Parallel Resonance

