Abstract:
Objective.To correlate numerical simulations of the electric dose distribution with early post-operative MRI following irreversible electroporation (IRE) treatment of hepatocellular carcinoma (HCC).Approach.A standard linear electrostatic model was employed to simulate the three-dimensional electric field (EF) distribution using real electric pulses and geometrical characteristics and intraoperative cone-beam CT (CBCT) data. Spatial registration between intraoperative CBCT and post-operative MRI was performed using both rigid and deformable methods, ranging from simple global translations based on anatomical landmarks to advanced deformable image registration (DIR) techniques accounting for elastic tissue deformations.Main results.The proposed approach was retrospectively evaluated using data from 22 patients who underwent IRE liver ablation (one patient underwent two distinct IRE procedures), resulting in a total of 23 procedures. The most accurate correspondence between predicted and observed ablation zones was achieved using a dose threshold of approximately 350 V cm-1, yielding a median dice similarity coefficient around 0.74, indicative of substantial spatial overlap. Although elastic DIR approaches applied to segmented liver regions provided the highest registration accuracy, the simpler translational registration based on manually selected landmarks demonstrated surprisingly robust performance in localizing the simulated EF within the actual ablation zone.Significance.These findings contribute to the standardization of IRE efficacy assessment on MRI and highlight the significant potential EF simulations to predict the extent of tissue ablation in IRE procedures for HCC. This approach may offer a valuable tool for improving intraoperative decision-making and post-operative assessment.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:57Author Spotlight: Advancing Pediatric Epilepsy Surgery in Children Through Novel Biomarkers and Enhanced Localization
Published on: September 20, 2024
Related Concept Videos
Calculation of Electric Flux
Voltmeter
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have finite...
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging