Elimination of Airborne Microorganisms Using Compressive Heating Air Sterilization Technology (CHAST): Laboratory and
Pritha Sharma1, Supriya Mahajan2, Gene D Morse3
1Department of Medicine, Yale New Haven Health, New Haven, CT 06610, USA.
Background:
Airborne transmission of bacteria, viruses, and fungal spores poses a major threat in enclosed settings, particularly nursing homes where residents are highly vulnerable. Compressive Heating Air Sterilization Technology (CHAST) applies compressive heating to inactivate microorganisms without reliance on filtration or chemicals.
Methods:
CHAST efficacy was evaluated in laboratory and deployed for a feasibility and performance validation study of air sterilization in a nursing home environment. Laboratory studies tested prototypes (300-5000 CFM; 220-247 °C) against aerosolized surrogates including Bacillus globigii (Bg), B. stearothermophilus (Bst), B. thuringiensis (Bt), Escherichia coli, and MS2 bacteriophage. Viral inactivation thresholds were further assessed by exposing MS2 to progressively lower treatment temperatures (64.5-143 °C). Feasibility and performance validation evaluation involved continuous operation of two CHAST units in a nursing home, with pre- and post-treatment air samples analyzed for bacterial and fungal burden.
Results:
Laboratory testing demonstrated consistent microbial inactivation, with most prototypes achieving > 6-log (99.9999%) reductions across bacterial spores, vegetative bacteria, and viruses. A 5000 CFM prototype achieved > 7-log (99.99999%) elimination of B. globigii. MS2 was completely inactivated at 240 °C, with modeling suggesting a threshold for total viral elimination near 170 °C. In the feasibility study, baseline sampling revealed bacterial (35 CFU/m3) and fungal (17 CFU/m3) contamination, dominated by Bacillus, Staphylococcus, Cladosporium, and Penicillium. After 72 h of CHAST operation, discharge air contained no detectable viable organisms, and fungal spore counts showed a 93% reduction relative to baseline return air. Units maintained stable operation (464 °F ± 2 °F; 329-335 CFM) throughout deployment.
Conclusion:
CHAST reproducibly and scalably inactivated airborne bacteria, viruses, and fungi under laboratory and feasibility field studies, supporting its potential as a chemical-free strategy to improve infection control and indoor air quality in healthcare facilities.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...