Related Experiment Video
Updated: Jan 13, 2026

Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
Intravascular ultrasound imaging with directional synthetic aperture focusing and coherence factor weighting
Hyunwoo Cho1, Jaebin Lee1, Daehyun Park1
1Department of Electronic Engineering, Sogang University, Seoul, Korea.
Purpose:
Intravascular ultrasound (IVUS) is widely used to visualize vascular structures and assess atherosclerotic plaques, particularly for evaluating the risk of rupture. Although increasing the center frequency of the transducer can enhance spatial resolution, it also increases attenuation, which substantially degrades image quality at greater depths. To mitigate this trade-off, synthetic aperture focusing (SAF) techniques have been studied; however, when applied to single-element rotational IVUS systems, they have yielded only minimal improvements and introduced undesirable artifacts.
Methods:
In this work, a directional SAF (dSAF) method is proposed to address these limitations. The convex nature of the point spread function in rotational IVUS scanning is analyzed to track the true direction of echo signals, enabling the selective exclusion of off-axis signals. By focusing only on valid signals during synthesis, resolution degradation and artifact formation are prevented, and the fidelity of the reconstructed image is preserved.
Results:
Validation through simulations and phantom experiments indicates that the dSAF method achieves an average 37.3% improvement in lateral resolution and an 8.6% increase in contrast-to-noise ratio, without degrading penetration depth.
Conclusion:
These findings suggest that directional echo screening effectively mitigates the limitations encountered with conventional SAF in IVUS imaging, offering a robust pathway to improved image quality. Additionally, the proposed approach can be integrated into existing IVUS workflows, potentially expediting clinical adoption and advancing intravascular diagnostic capabilities.
More Related Videos
07:14Dual Raster-Scanning Photoacoustic Small-Animal Imager for Vascular Visualization
Published on: July 15, 2020
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...