Related Experiment Video
Updated: Jan 12, 2026

07:57
Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
13.9K
Comparison and Accuracy of Different Impression Procedures Utilizing Hex and Non-Hex Impression Copings
Ashwini M Kattimani1, Sudhindra Mahoorkar1, Swati M Devani1
1Department of Prosthodontics and Implantology, H.K.E.S' S. Nijalingappa's Institute of Dental Sciences and Research, Kalaburagi, Karnataka, India.
Journal of Pharmacy & Bioallied Sciences
|October 30, 2025
Summary
Non-Hex impression copings offer superior accuracy for implant-supported prostheses, especially in angled implant situations. This study recommends their use for improved prosthetic fit in nonparallel conditions.
Area of Science:
- Dental prosthetics
- Implant dentistry
- Impression techniques
Background:
- Accurate impressions are critical for passive fit in implant-supported prostheses.
- Impression accuracy can be significantly affected by factors like coping design and implant angulation.
Purpose of the Study:
- To compare the accuracy of different impression procedures using Hex and Non-Hex impression copings.
- To evaluate these procedures in multiple implant conditions with varying angulations.
Main Methods:
- An in vitro study utilized three mandibular edentulous acrylic models with implant angulations of 0°, 5°, and 10°.
- Hex and Non-Hex copings were tested in Hex-Hex, Hex-Non-Hex, and Non-Hex-Non-Hex configurations using the open-tray technique.
- Deviations were measured on master casts and reference models scanned with a Medit T300 scanner.
Main Results:
- The Non-Hex-Non-Hex configuration demonstrated the least deviation across all axes in 5° and 10° angulated models.
- The Hex-Hex combination consistently showed the highest deviation values.
- Statistically significant differences (P < 0.05) in impression accuracy were observed, particularly in angulated conditions.
Conclusions:
- Non-Hex impression copings yield superior accuracy for multiple and angulated implant impressions.
- Clinical recommendation for Non-Hex copings in nonparallel implant conditions to enhance prosthetic fit.