Visual Performance and Refractive Stability of Clareon® Monofocal Intraocular Lens Implanted with an Automated
Edward Tran1,2, Nirmit Shah2,3, Sandra Caballero Ortiz2
1Schulich School of Medicine, University of Western Ontario, London, ON, Canada.
Clinical Ophthalmology (Auckland, N.Z.)
|October 30, 2025
Summary
The Clareon monofocal intraocular lens (IOL) showed excellent visual performance and refractive stability in cataract surgery patients. This study found no glistenings, confirming its sustained optical clarity and reliability.
Area of Science:
- Ophthalmology
- Biomedical Engineering
Background:
- Cataract surgery involves implanting intraocular lenses (IOLs) to restore vision.
- Assessing the long-term performance and optical clarity of new IOLs is crucial for patient outcomes.
Purpose of the Study:
- To evaluate the visual performance and refractive stability of the Clareon monofocal intraocular lens (IOL).
- To assess the glistening-free optical clarity of the Clareon IOL when implanted using the AutonoMe automated delivery system.
- To examine the real-world effectiveness of this IOL and delivery system combination in North America.
Main Methods:
- A prospective, single-arm study was conducted with 46 patients (85 eyes) undergoing cataract surgery.
- Patients received the Clareon monofocal IOL via the AutonoMe delivery system.
- Visual acuity (UDVA, BCDVA, LCVA) and refractive error were measured at 1, 3, and 12 months postoperatively.
- IOL glistening was assessed using the Miyata scale at 3 and 12 months.
Main Results:
- No statistically significant changes in manifest refraction, uncorrected (UDVA), or best-corrected distance visual acuity (BCDVA) were observed between 1 and 3 months.
- Mean spherical equivalent was +0.09 D with low residual astigmatism (-0.33 D) at 3 months.
- Mean logMAR UDVA and BCDVA were 0.13 and 0.02, respectively, with LCVA at 0.04 logMAR.
- No glistenings were observed in any patient at 3 or 12 months postoperatively.
- Refractive and visual outcomes remained stable, with no device-related complications.
Conclusions:
- The Clareon monofocal IOL demonstrated excellent refractive accuracy and stable visual performance up to one year.
- The IOL maintained sustained optical clarity with no observed glistenings.
- The Clareon IOL, used with the AutonoMe delivery system, is a reliable option for cataract surgery.
Related Concept Videos
Angle Closure Glaucoma: Treatment
1.1K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.1K
Open Angle Glaucoma: Treatment
951
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
951