Related Experiment Video
Updated: Jan 12, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Validity of an open-source mobile app to measure fractal correlation properties of heart rate variability during
Bruce Rogers1, Juan M Murias2, Pablo R Fleitas-Paniagua3,4
1College of Medicine, University of Central Florida, Orlando, FL, USA.
Purpose:
The nonlinear index of heart rate (HR) variability (HRV), based on detrended fluctuation analysis (DFA a1), is recognized for its value in assessing endurance exercise intensity thresholds and autonomic durability. However, a constraint to widespread implementation is lack of a low cost, real-time solution. This study examined whether a free, open-source Android application (Fatmaxxer) could provide reasonable agreement and correlation with the established standard of Kubios HRV software.
Methods:
Twenty-three participants (10 males) underwent incremental step-ramp-step cycling testing measuring gas exchange variables with recording of raw RR intervals and Fatmaxxer computed DFA a1. The raw RR series was processed by Kubios HRV software for comparisons of HRV HR thresholds (HRVTK vs. HRVTFM), DFA a1 responses during the entire incremental ramp and average DFA a1 computed from a post ramp constant intensity interval performed in the heavy domain.
Results:
Based on t testing, Wilcoxon sign rank testing and Bland Altman analysis, there were small differences present in the direct comparison of DFA a1 responses in the incremental ramp and 10-minute constant interval (bias 0.03-0.05 respectively). Despite this bias, the mean HRVT1/2 determinations were within 1 bpm and the first HRVT comparisons equivalent. All regressions showed excellent alignment with Pearson's r/Spearman's correlation/ICC above 0.96.
Conclusions:
The DFA a1 responses and HRVTs derived from Fatmaxxer closely aligned with those obtained from the established standard Kubios HRV software. This highlights the utility of Fatmaxxer as a free, open-source Android platform capable of real-time monitoring, supporting broader accessibility of DFA a1 tracking.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring pulse
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes