Related Experiment Video
Updated: Jul 27, 2026

Simultaneous Transcranial Alternating Current Stimulation and Functional Magnetic Resonance Imaging
Published on: June 5, 2017
Decoding paradoxical BOLD responses to transcranial ultrasound stimulation with concurrent optoacoustic magnetic
Yi Chen1,2, Zhenyue Chen3, Hector Estrada1,2
1Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, University of Zürich, Zürich, Switzerland.
Abstract:
Focused transcranial ultrasound stimulation (TUS) can affect neural activity with high spatial precision, advancing noninvasive neuromodulation toward targeted treatment of brain disorders. Direct monitoring of TUS responses is crucial for ensuring optimal outcomes. Blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging has primarily been used for studying TUS effects in both human and nonhuman primate brains. However, the physiology and mechanisms underlying BOLD remain largely unknown due to its highly convoluted nature. To address these limitations, we developed a hybrid system for concurrent optoacoustic and magnetic resonance imaging of TUS (OMRITUS) to comprehensively characterize the hemodynamic changes in murine brains. Our findings reveal paradoxical negative BOLD signals in the activated cortical regions, coupled with increased total hemoglobin levels simultaneously monitored with optoacoustic tomography. Multispectral optoacoustic readings further demonstrated a stronger increase in deoxygenated versus oxygenated hemoglobin, suggesting a potential molecular basis for the negative BOLD responses. OMRITUS enables the study of complex TUS-hemodynamic interactions, paving the way for precise neuromodulatory interventions.
More Related Videos
11:57Whole-Brain 3D Activation and Functional Connectivity Mapping in Mice using Transcranial Functional Ultrasound Imaging
Published on: February 24, 2021
09:34A Methodological Protocol and Considerations for Transcranial Ultrasonic Stimulation in Exploratory Clinical Human Studies
Published on: December 12, 2025
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Atomic Nuclei: Magnetic Resonance
NMR Spectrometers: Resolution and Error Correction
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Magnetic Resonance Imaging
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...