Related Experiment Video
Updated: Jan 12, 2026

Measuring Post-Stroke Cerebral Edema, Infarct Zone and Blood-Brain Barrier Breakdown in a Single Set of Rodent Brain Samples
Published on: October 23, 2020
Non-Contrast Assessment of Blood-Brain Barrier Permeability to Water: Improved Signal Modeling and Data Acquisition
Wen Shi1,2, Jiani Wu1,2, Yifan Gou1,2
1Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Purpose:
Water-extraction-with-phase-contrast-arterial-spin-tagging (WEPCAST) MRI is a non-contrast method to estimate the blood-brain barrier (BBB) permeability to water. Similar to other arterial-spin-labeling (ASL) based techniques, signal-to-noise ratio is a limitation. This study aims to enhance its reliability via theoretical and experimental improvements.
Methods:
We propose a generalized-venous-signal (GVS) model to describe the signal evolution of WEPCAST MRI, with which the control and labeled signals can be utilized to simultaneously estimate the water extraction fraction (E) and venous transit time (VTT). We conducted studies to test its feasibility and inter-visit reproducibility. We further made an experimental improvement by adding a 1-min blood T1 scan and investigating its benefit in reducing inter-subject variations.
Results:
When applying the GVS model-based method at different locations along the superior sagittal sinus (SSS), VTT increased from anterior to posterior segments while E remained constant, consistent with known physiology. BBB permeability-surface-area-product (PS) revealed a significantly lower CoV of 5.0% ± 4.1% when using the GVS method, in comparison with 8.9% ± 6.5% using the peak-detection method (p = 0.002). Blood T1 was found to be 1725.7 ± 37.2 ms in males and 1799.2 ± 122.4 ms in females. After including subject-specific blood T1 in the parametric estimation, inter-subject CoV in PS was found to be 6.8%, compared with a CoV of 14.2% when using an assumed blood T1 (p = 0.004). VTT estimated from WEPCAST was consistent with that measured with a dedicated sequence (R = 0.757, p = 0.011).
Conclusion:
The reliability of WEPCAST MRI for the measurement of BBB permeability can be improved by incorporating GVS model and individual blood T1.