Clinical and Radiographic Performance of Two Distinct Sandblasted, Large-Grit, Acid-Etched Implant Surfaces: A Split-Mouth Randomized Clinical Trial
Related Experiment Video
Updated: Aug 3, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Blanca Vílchez1, Leticia Caneiro2, Cristina Lima1
1Postgraduate Clinic of Periodontology, School of Dentistry, University Complutense of Madrid, Madrid, Spain.
Aim:
To compare the clinical performance of two sandblasted, large-grit, acid-etched implant surfaces regarding changes in radiographic marginal bone level (MBL) 12 months after loading.
Materials And Methods:
In this randomized, split-mouth, dual-center clinical trial, each patient received one test (modified hydrophilic surface) implant and one control (conventional surface) implant. The primary endpoint was the change in MBL measured 12 months after loading. Secondary outcomes included the assessment of soft tissue wound healing index (WHI), adverse events, implant stability quotient (ISQ), peri-implant soft tissue parameters (probing pocket depth, bleeding on probing, keratinized mucosa width), and oral health-related quality of life (OHRQoL) measured with the Oral Health Impact Profile-14 (OHIP-14). Generalized linear models, paired Student's t-tests, and Wilcoxon tests were employed for data analysis.
Results:
The study included 68 subjects (136 implants). No statistically significant differences were found between groups for any of the clinical outcomes measured. The mean change in MBL from loading to 12 months was 0.04 mm (SD = 0.39) for the modified hydrophilic implants and 0.07 mm (SD = 0.22) for the conventional implants (p = 0.658), with no significant differences between the groups.
Conclusions:
Over a 12-month period of functional loading, both implant surfaces demonstrated comparable performance regarding peri-implant bone stability, safety, and clinical outcomes. Although a small but statistically significant difference between groups was observed in MBL changes from baseline to 12 months (MD = 0.15 mm), no significant differences were found in MBL changes from loading to 12 months (primary outcome), ISQ, soft tissue healing, or peri-implant health.
More Related Videos
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025