Related Experiment Video
Updated: Jan 12, 2026

Two-Dimensional Super-Resolution Visualization of Rat Brain Microvasculature Using Ultrasound Localization Microscopy
Published on: March 28, 2025
Ultrasound super-resolved hemodynamic estimation in microvessel using physics-informed neural networks and data
Meiling Liang1, Jiacheng Liu1, Hao Wang1
1The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of life Science and Technology, Xi'an Jiaotong University, Xi'an, China.
Background And Objective:
Ultrasound super-resolution imaging (SRI) enables the visualization of microvascular structure and velocity, but enhancing the spatial resolution of instantaneous velocity field and simultaneously capturing pressure field remains challenging.
Methods:
This study proposes a method combining physics-informed neural networks (PINN) with data assimilation to assist microvascular two-dimensional (2D) super-resolution velocity and pressure reconstruction in SRI. Specifically, long-time velocity vector set acquired via SRI is decomposed into short-time subsets, with vectors in each subset stacked and treated as simultaneous to enhance spatial information. These are then matched and fused with the hemodynamic simulation based on the SRI-derived structure and flow information via data assimilation, generating a new velocity field that effectively filling gaps in sparse measurements. This velocity is used to optimize the PINN encoded with the 2D Navier-Stokes equations to reconstruct the super-resolution velocity field and infer reliable pressure field.
Results:
In vitro experiments validated the method's performance and investigated the influence of the data amplification factor on the reconstruction accuracy, with the spatial vectors number increased by 6.48 times. Meanwhile, the super-resolution hemodynamic parameter reconstructions of rat brain microvessels and liver tumor peritumoral vessels aligned with the velocity measured by conventional SRI (rat brain vessels: radial resolution of 0.46 μm and axial resolution of 5.9 μm, liver tumor vessels: radial resolution of 5.5 μm and axial resolution of 123 μm), and the relative errors are 1.85% and 4.89%, respectively.
Conclusions:
The proposed method reconstructs super-resolution microvascular velocity and pressure from sparse, inhomogeneous 2D SRI velocity data, showing powerful potential for aiding clinical diagnosis of microvascular diseases. (ClinicalTrials.gov (NCT06018142)).