Related Experiment Video
Updated: Jan 12, 2026

Examination of Rapid Dopamine Dynamics with Fast Scan Cyclic Voltammetry During Intra-oral Tastant Administration in Awake Rats
Published on: August 12, 2015
Straightforward screening of ketamine in forensic samples using voltammetry with screen-printed carbon graphite
Camila D Lima1, Lara L Machado2, Luciano C Arantes3
1Departamento de Química, Universidade Federal de Minas Gerais, 31270-901, Belo Horizonte, Minas Gerais, Brazil.
Abstract:
Ketamine (KET) is a controlled psychoactive substance widely misused for its stimulant and dissociative effects. Known by street names such as "Special-K," "Happy Water," "K Powdered Milk," "Pink Cocaine," and "Party Lollipops," its growing prevalence in illicit drug markets has raised significant public health and forensic concerns. In this work, an electrochemical method was developed for the selective and straightforward detection of KET in forensic samples using screen-printed carbon graphite electrodes (SPE-Gr) and differential pulse voltammetry (DPV). KET exhibited two oxidation peaks and, for the first time, three distinct reduction processes on a working electrode surface. Two of these cathodic peaks enable reliable differentiation of KET from several other drugs. The optimized method, based on Britton-Robinson buffer (0.1 mol L-1, pH 7.0), produced highly reproducible responses, with relative standard deviations (N = 3) below 3.0 % for peak currents and below 1.0 % for peak potentials. Linear dynamic ranges were established for oxidation (3.7-54 μmol L-1) and reduction (15-100 μmol L-1) processes, with corresponding detection limits of 0.5 μmol L-1 and 4.5 μmol L-1. Interference studies confirmed the method's ability to discriminate KET from major interfering substances, including MDMA (ecstasy), MDA, amphetamine, methamphetamine, and cocaine. The approach also demonstrated reliable detection of KET in reference material certified by the United Nations Office on Drugs and Crime (UNODC), in addition to demonstrating excellent performance in the analysis of seized street samples. Overall, the proposed method is well-suited for straightforward, selective, and portable screening of KET in forensic contexts.
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Pulse Voltammetry
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry

