Clinical Outcomes of Collagen-Based Nasal Packing in Endoscopic Dacryocystorhinostomy
1Department of Ophthalmology, Korea University College of Medicine, Anam Hospital, Seoul, South Korea.
Objectives:
Endoscopic dacryocystorhinostomy (Endo DCR) is a standard treatment for nasolacrimal duct obstruction, though outcomes may be compromised by intraoperative bleeding and postoperative inflammation. This study evaluated the clinical efficacy of Novacol Fibrillar®, a collagen-based absorbable hemostatic agent, in Endo DCR.
Methods:
A retrospective review was conducted on 357 patients who underwent Endo DCR from January 2018 to September 2024. The Novacol group (n = 168) received Novacol packing, while the Nasopore group (n = 189) received Nasopore. Primary outcomes included anatomical and functional success, operative time, and intraoperative bleeding. Secondary outcomes included granulation, infection, epistaxis, postnasal drip, and revision surgery within 3 months.
Results:
The Novacol group showed higher anatomical (94.6% vs 85.2%, P = .039) and functional (93.5% vs 84.1%, P = .023) success. Intraoperative bleeding was lower (9.5 vs 12.4 gauzes, P = .022), as were rates of granulation (9.5% vs 24.3%, P = .009), epistaxis (5.4% vs 21.7%, P = .028), postnasal drip (6.5% vs 23.3%, P = .032), and revision surgery (2.4% vs 16.4%, P = .041). Infection rates were not significantly different (P = .083).
Conclusions:
Novacol Fibrillar improved surgical outcomes and reduced complications in Endo DCR, supporting its use as an effective hemostatic packing material.
More Related Videos
06:13Endoscopic Septoplasty with Limited Two-line Resection: Minimally Invasive Surgery for Septal Deviation
Published on: June 20, 2018
09:07Author Spotlight: Advancing Endoscopic Ossiculoplasty – Techniques, Innovations, and Practical Guidance for Clinical Integration
Published on: January 26, 2024
Related Concept Videos
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: