Related Experiment Video
Updated: Jan 11, 2026

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
Published on: March 8, 2019
Performance of the First Spiral Refractive Intraocular Lens for Continuous Full Range of Vision
Claudette Abela-Formanek1, Michael Amon2, Gerd U Auffarth3
1The Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.
Purpose:
To evaluate visual performance of a novel full range of vision spiral intraocular lens (IOL) designed with artificial intelligence using preclinical and clinical metrics.
Methods:
Preclinical visual performance was assessed in healthy individuals using a pseudophakic vision simulation device, comparing monocular corrected distance visual acuity, contrast sensitivity, defocus curve, halo/glare size, and subjective preference between the spiral RayOne Galaxy IOL and diffractive RayOne Trifocal IOL (Rayner). Additionally, postoperative clinical outcomes were subsequently analyzed from 10 sites following bilateral RayOne Galaxy IOL implantation. At 3 months postoperatively, key endpoints included subjective refraction, monocular and binocular uncorrected and corrected distance visual acuity at multiple distances, defocus curves, and patient-reported dysphotopsia.
Results:
Preclinical evaluation demonstrated comparable range of focus between the Galaxy and diffractive Trifocal IOLs. However, the Galaxy IOL exhibited significantly less halo/glare, with nearly all participants preferring it across all distances. In the clinical study, mean monocular corrected distance visual acuities were -0.03 ± 0.08 logarithm of the minimum angle of resolution (logMAR) for distance, 0.05 ± 0.11 logMAR for intermediate, and 0.08 ± 0.14 logMAR for near, with further improvement observed binocularly. Monocular/binocular defocus curves demonstrated a smooth plateau with binocular defocus maintaining visual acuity of 20/32 (0.2 logMAR) or better from +1.00 to -2.80 diopters (35 cm). Halo and glare symptoms were generally minor (> 95% of patients), with no severe cases.
Conclusions:
The Galaxy IOL provides excellent monocular and binocular visual acuity across all tested distances, with a smooth and continuous defocus curve ensuring full-range vision. Preclinical testing demonstrated significantly fewer photic phenomena than the tested diffractive trifocal IOL, whereas clinical investigations found no indications of bothersome side effects, together demonstrating high visual comfort.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye
Glaucoma: Overview