Partially coherent persistent hollow beams enabled by cross-phase modulation

Optics Express
|November 11, 2025
PubMed
Abstract

Related Concept Videos

Beams with Symmetric Loadings01:15

Beams with Symmetric Loadings

The moment-area method is an analytical tool used in structural engineering to determine the slope and deflection of beams under various loads. Consider a cantilever with a concentrated load and moment at the free end. The first step is constructing a free-body diagram to calculate the reactions at the fixed end. Next, the bending moment diagram is plotted to visualize how the bending moment varies along the beam's length, focusing on points where the bending moment equals zero.
The M/EI...
377
Beams with Unsymmetric Loadings01:17

Beams with Unsymmetric Loadings

Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
390
Impact Loading on a Cantilever Beam01:13

Impact Loading on a Cantilever Beam

The analysis of a cantilever beam with a circular cross-section subjected to impact loading at its free end illustrates the conversion of potential energy from a dropped object into kinetic energy, which is then absorbed by the beam as strain energy. This process is crucial for understanding how materials behave under dynamic loads, which is important in fields such as construction and aerospace.
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
834
Interference: Path Lengths01:10

Interference: Path Lengths

Consider two sources of sound, that may or may not be in phase, emitting waves at a single frequency, and consider the frequencies to be the same.
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
1.8K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
411
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
473