Related Experiment Video
Updated: Jan 11, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
The effects of a new device on mechanical complications of short peripheral intravenous catheters: A randomized
Christopher Blacker1, Ali-Reza Modiri2, Gustaf Ljungman1
1Department of Women's and Children's Health, Uppsala University, Uppsala, Sweden.
Background:
Placement of a short peripheral catheter (SPC) is one of the most common invasive procedures in healthcare. Catheter dysfunction occurs in up to 69%, caused by phlebitis, subcutaneous infiltration, occlusion, and dislodgement, conjointly considered as mechanical complications. Recent research has indicated that a new type of medical device, the force-activated separation device (FASD), may reduce these mechanical complications by 46%, but efficacy and safety data are lacking. The objective of this study was to investigate the efficacy and rate of adverse events (AEs) using a novel FASD.
Method:
This was a single center randomized controlled trial comparing a FASD to standard of care, where primary outcome was rate of mechanical complications for each arm. Adult patients, admitted to either a stroke ward or orthopedic ward at a University Hospital were eligible.
Results:
The population was mainly male, elderly, and had multiple co-morbidities. The study included 146 patients, contributing with a total of 194 catheters for the per protocol (PP) and 203 for the intention to treat (ITT) analyses. In the PP analysis, the total mechanical complication rate was 42% versus 46% (p = 0.56), while the dislodgement rate was 3.4% versus 12% (p = 0.04) in the intervention and control group, respectively. For ITT, total mechanical complication rate was 42% versus 47% (p = 0.47) and the dislodgement rate was 4.2% versus 13% (p = 0.03) in the intervention and control groups. FASD implementation resulted in a 73% reduction in dislodgements in the PP, and a 68% reduction in the ITT analysis. No device related AEs were recorded.
Conclusion:
The implementation of a novel FASD did not demonstrate a reduction of total mechanical complications, however, a 73% reduction in dislodgements in the PP, and a 68% reduction in the ITT analysis was noted. No device-related AEs were recorded.Clinical Trials; clinicaltrials.gov; ID: NCT05814887.
More Related Videos
10:09Drug Treatment by Central Venous Catheter in a Mouse Model of Angiotensin II Induced Abdominal Aortic Aneurysm and Monitoring by 3D Ultrasound
Published on: August 4, 2022
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...