Related Experiment Video
Updated: Apr 30, 2026

Single-cell Analysis of Immunophenotype and Cytokine Production in Peripheral Whole Blood via Mass Cytometry
Published on: June 26, 2018
Sequential versus Simultaneous Quantitative Analysis of Biomarkers in Individual Cells by ICP-MS and Mass Cytometry:
Ángela de la Rosa-Díaz1,2, Christian Sordo-Bahamonde2,3,4, Segundo Gonzalez2,3,4
1Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, c/Julián Clavería 8, Oviedo 33006, Spain.
Abstract:
Quantification strategies to establish the content of different elements in individual cells are crucial for elucidating any kind of biological conclusion. Technically, this process is hampered when using inductively coupled plasma mass spectrometry (ICP-MS) with nonsimultaneous mass analyzers. This work aims to establish under which set of conditions the sequential and simultaneous detection of different elements in individual cells provides comparable results. Thus, endogenous elements (P and Fe) and Ir as an exogenous cell marker are sequentially measured and quantified using ICP-MS revealing that cell storage and dilution conditions are more critical than cell deposition within the sample introduction device. Under optimized conditions, the interaction of an immunotherapeutic agent (Rituximab) that directs against the B-lymphocyte antigen called cluster of differentiation 20 (CD20) on a B-cell chronic lymphocytic leukemia cell line (MEC-1) is quantified using both single-cell analysis by ICP-MS (SC-ICP-MS) and mass cytometry (CyTOF) after labeling with Lu. Although the obtained values are in good agreement, a general trend is observed with a slight bias toward higher results in SC-ICP-MS versus CyTOF probably ascribed to the automated data treatment system used in CyTOF, discarding double cell events. Both analytical approaches (SC-ICP-MS and CyTOF) showed comparable levels of CD20 expression around 1 × 104 receptors/cell in good agreement with the literature, proving the suitability of a similar calibration strategy for both instruments. The application of CyTOF quantification strategies has permitted the analysis of CD20 in healthy subjects and patient samples as proof of concept for the applicability of the proposed work.
More Related Videos
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
08:25Mass Cytometry Analysis of Systemic and Local Immune Responses in Hepatocellular Carcinoma
Published on: April 25, 2025
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview