Efficiency of 80% vs. 100% Oxygen for Preoxygenation: A Randomized Study on Duration of Apnoea Without Desaturation
Jaewoong Jung1, Yang-Hoon Chung1, Bon-Sung Koo1
1Department of Anaesthesiology and Pain Medicine, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon-Si 31538, Republic of Korea.
Abstract:
Background/Objectives: Preoxygenation with 100% oxygen is commonly used but poses risks such as hyperoxia and atelectasis. Using 80% oxygen may reduce these effects but shortens duration of apnoea without desaturation (DAWD). This study compared preoxygenation efficiency between 80% and 100% oxygen and evaluated changes in the Oxygen Reserve Index™ (ORi™). Methods: Patients undergoing elective laparoscopic cholecystectomy were randomized to preoxygenation with 80% or 100% oxygen. Adequate preoxygenation was defined as a ≤10% difference between fraction of inspired oxygen and end-tidal oxygen (EtCO2). The primary outcome was DAWD, the interval from apnoea onset to peripheral oxygen saturation (SpO2) of 93%. Secondary outcomes included time to adequate preoxygenation and additional warning time from ORi™ zero to SpO2 97%. Results: Thirty patients were randomised to 80% (n = 15) or 100% oxygen (n = 15) oxygen groups. One patient in the 100% group was excluded due to spontaneous breathing before SpO2 93%, leaving 29 for DAWD analysis. DAWD was 345 ± 136 s (80%) and 430 ± 163 s (100%) with a mean difference of 86 s (p = 0.135). No significant differences were observed in tie to adequate preoxygenation or additional warning time. Conclusions: Preoxygenation with 80% oxygen resulted in a numerically shorter DAWD compared with 100% oxygen, without a significant difference in ORi™. These findings may suggest the potential feasibility of using 80% oxygen for preoxygenation. However, given the limited sample size and uncertain clinical relevance, further large-scale studies are warranted to clarify the safety and clinical implications of lower oxygen concentration during anaesthesia induction.
More Related Videos
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...