Related Experiment Video
Updated: Jan 11, 2026

Preparation of Liquid Crystal Networks for Macroscopic Oscillatory Motion Induced by Light
Published on: September 20, 2017
Optical-Structural Optimization for Condensation Suppression in Automotive Camera Modules
Kouwen Zhang1,2, Yike Xu2, Shenwei Xu2
1State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China.
None:
Cameras have become indispensable sensors in intelligent vehicles, with their deployment steadily increasing across modern automobiles. It is critical for camera modules to have reliable and accurate environmental perception, but a major challenge is condensation inside the modules that severely compromises imaging quality. To address this issue, we performed comprehensive thermodynamics-based simulations to clarify condensation mechanisms and evaluate their impact on optical imaging performance. Based on these insights, we proposed an integrated optical-structural optimization strategy that reduces the internal cavity volume adjacent to the first lens, simultaneously increasing the first lens thickness and the curvature of its internal surface. This strategy both reduces water vapor volume and elevates the temperature of potential condensation zones. The optimized module exhibits markedly improved resistance to condensation compared with the baseline design in the experiment, raising the critical condensation threshold from a sudden temperature drop of 42 °C to over 60 °C. This approach effectively mitigates condensation under harsh environmental conditions without additional cost. Our simple yet effective design is broadly applicable to diverse automotive camera module architectures, thereby enhancing system reliability and improving the overall safety of autonomous driving.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...

