Related Experiment Video
Updated: Jan 11, 2026

Long-term Continuous EEG Monitoring in Small Rodent Models of Human Disease Using the Epoch Wireless Transmitter System
Published on: July 21, 2015
Real-Time Rail Electrification Systems Monitoring: A Review of Technologies
Jose A Sainz-Aja1, João Pombo2,3,4, Jordan Brant2
1LADICIM (Laboratory of Science and Engineering of Materials), University of Cantabria, 39005 Santander, Spain.
Abstract:
Most electrified railway networks are powered through a pantograph-overhead contact line (OCL) interface to ensure safe and reliable operation. The OCL is one of the most vulnerable components of the train traction power system as it is subjected to multiple impacts from the pantographs and to unpredictable environmental conditions. Wear, mounting imperfections, contact incidents, weather conditions, and inadequate maintenance lead to increased degradation of the pantograph-OCL current collection performance, causing degradation on contacting elements and assets failure. Incidents involving the pantograph-OCL system are significant sources of traffic disruption and train delays, e.g., Network Rail statistics show that, on average, delays due to OCL failures are 2500 h per year. In recent years, maintenance strategies have evolved significantly with improvements in technology and the increased interest in using real-time and historical data in decision support. This has led to an expansion in sensing systems for structures, vehicles, and machinery. The railway industry is currently investing in condition monitoring (CM) technologies in order to achieve lower failure rates and increase the availability, reliability, and safety of the railway service. This work presents a comprehensive review of the current CM systems for the pantograph-OCL, including their advantages and disadvantages, and outlines future trends in this area.
Related Concept Videos
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Differential Relays
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...

