Systematic errors in isothermal titration calorimetry: The role of feedback power and effects of mixing and diffusion
Žiga Medoš1, Marija Bešter-Rogač1, Epameinondas Leontidis2
1Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, 1000, Ljubljana, Slovenia.
Abstract:
Using experiments based on the NaCl dilution calibration method, we examine several previously unstudied instrumental effects that can lead to systematic errors in isothermal titration calorimetry (ITC). We confirm earlier results that power feedback can affect estimated heats and find further that it can also affect cell temperature and introduce temperature "noise." To estimate effects from loss of titrant from the syringe through diffusion, and concentration changes in the cell from mixing with the overflow volume, we conduct experiments with injections separated by time intervals Δt from 8 to 60 min, giving run durations from 6 h to over 2 days. Because the effects are small, we have developed a global least-squares fitting algorithm to analyze 20 datasets simultaneously, from which three parameters governing diffusion and mixing ("leakage") are estimated, along with calibration parameters for heat and cell volume. Expressed as an effective volume loss from the syringe, Δvdif is found to be of order ∼0.03 μL per injection for NaCl into water. Its effect is predicted to be negligible in many ITC applications. The effects from leakage are more significant but their neglect is still predicted to affect both NaCl calibration and 1:1 binding results by ∼1 %, which is marginally significant for calibration but seldom so for 1:1 binding. The calibration results for the cell volume V0 are particularly sensitive to temperature and to the literature source for the relative molar enthalpy function for NaCl(aq).
Related Concept Videos
Constant Pressure Calorimetry
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Random and Systematic Errors
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Calorimetry
Constant Volume Calorimetry