Related Experiment Video
Updated: Jan 11, 2026

Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
A Flexible RF Coil Design (OxyTrack) for Oxygen Measurements in Body Cavities
Conner S Ubert1,2, Sergey V Petryakov1, Maciej M Kmiec1
1Department of Radiology, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire, USA.
Purpose:
Electron paramagnetic resonance (EPR) spectroscopy enables quantitative measurement of tissue oxygen levels. The conventional single-loop EPR resonator designs limit the oxygen measurements to superficial tissues within 1-3 cm depth and inadequately address clinical requirements for deep-tissue oxygen monitoring in anatomically complex regions and confined body cavities. The aim of this study was to develop a flexible RF coil-based sensor (OxyTrack) designed for real-time oxygen measurements in complex anatomical environments that are typically inaccessible to conventional rigid coil configurations.
Methods:
The RF coil configuration of the OxyTrack included a catheter-like, flexible design that incorporates the OxyChip (oxygen sensor) in the resonant loop. A modified coaxial cable arrangement with braided shielding was used for cavity measurements. The constructed coil/sensor was evaluated for power saturation thresholding, oxygen sensitivity (calibration), mechanical stability, and integrity of the coil under various stress conditions. Biological validation studies were performed to test dynamic oxygen variations in the gastrointestinal tract (GI) of murine subjects.
Results:
The flexible OxyTrack exhibited an oxygen sensitivity of 14.8 mG/mmHg with a linear response across physiological ranges (0-160 mmHg), maintaining signal integrity under various mechanical stresses. In vivo validation experiments in mice GI tracts demonstrated statistically significant discrimination of rectal tissue oxygenation between normoxic (0.52 ± 0.04 mmHg) and hyperoxic conditions (6.43 ± 0.24 mmHg) with p < 0.001. Pre-clinical imaging compatibility established the absence of significant artifacts.
Conclusion:
This flexible RF coil sensor enables minimally invasive, real-time oxygen monitoring in complex anatomical locations, with implications for pre-clinical research and potential clinical translation in oxygen-related pathophysiology assessment.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...