Background:
There continues to be controversy regarding the optimal fixation strategy of large posterior malleolar fractures while treating trimalleolar ankle fractures. This study compared the biomechanical stability in a cadaveric model of a modified anterior-posterior (AP) 4-screw construct vs posterior plate fixation of Mason 2A posterior malleolar fractures.
Methods:
Twenty fresh frozen human cadaveric below-knee specimens were prepared with an oblique osteotomy of the posterior malleolus, resection of medial and lateral ankle ligaments, and posterior dislocation of the tibiotalar joint to produce unstable Mason 2A posterior malleolar fractures. Specimens were fixed with either a modified AP 4-screw construct or with a 5-hole one-third tubular plate with 4 cortical screws. The specimens were axially loaded in neutral ankle position for 50 000 cycles to simulate protected weightbearing, then loaded to failure in 20 degrees of plantarflexion. Fracture displacement and load to failure were recorded.
Results:
Two specimens from the plate group had early failure with displacement at the fracture site >2 mm; otherwise, there was no difference in displacement between the 2 constructs after axial cyclic loading (screws, 1.32 ± 0.26 mm vs plate, 1.26 ± 0.48 mm, P = .82). Additionally, there was no difference in the load to failure (screws, 3856 ± 617 N vs plate, 3939 ± 569 N, P = .81). Maximum load to failure was statistically equivocal between the 2 constructs (screws, 4867 ± 718 N vs plate, 4862 ± 1020 N, P = .99).
Conclusion:
For the fixation of large, unstable Mason 2A posterior malleolar fractures involving roughly 50% of the articular surface, our modified AP 4-screw construct may offer similar biomechanical stability while avoiding prone positioning and additional posterior surgical exposures associated with posterior plating.
Clinical Relevance:
This cadaveric study demonstrates that a modified anterior-posterior 4-screw construct provides biomechanical stability equivalent to posterior plating for large posterior malleolar fractures.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Bone Structure
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...