Background:
Dysphagia in Huntington's disease (HD) has been described using instrumentation. However, no research has evaluated reliability of swallowing measures in this population.
Objectives:
This study evaluated the test-retest reliability of swallowing measures in HD.
Methods:
Ten participants with HD and dysphagia were assessed at three intervals over 1 week. Functional measures of swallowing included the Timed Water Swallow Test (TWST) and Test of Masticating and Swallowing Solids (TOMASS). Swallowing biomechanics were measured using manofluoroscopy and ultrasound.
Results:
Nine participants completed all assessments. Results indicated good to excellent reliability (ICC >0.75) in 5/7 parameters of functional assessments (TWST/TOMASS) and moderate to excellent reliability (ICC >0.5) in 4/6 ultrasound measures. Manometric measures produced poor test-retest reliability (ICC <0.5). Videofluoroscopy measures ranged from poor to moderate reliability (ICC <0.5 to <0.75).
Conclusions:
Swallowing measures showed mixed reliability in HD. This data can guide the selection and interpretation of outcomes in subsequent studies.