Related Experiment Video
Updated: May 10, 2026

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
P-Wave Parameter Changes After Pulsed-Field Ablation, Cryoballoon Ablation and Radiofrequency Ablation for Paroxysmal
Ibrahim Antoun1,2, Ahmed Abdelrazik1,2, Xin Li3
1Department of Cardiology University Hospitals of Leicester NHS Trust, Glenfield Hospital Leicester UK.
Background:
Pulmonary vein isolation (PVI) is central to controlling paroxysmal atrial fibrillation (AF). Pulsed-field ablation (PFA) offers a non-thermal alternative to conventional thermal techniques. The study compares changes in P-wave parameters following PFA, radiofrequency ablation (RF), and cryoballoon ablation (Cryo).
Methods:
We retrospectively analysed 283 patients undergoing first-time PVI (RF 101, Cryo 125, PFA 57). Digital electrocardiograms (ECGs) were evaluated for P-wave duration (PWD), voltage (PWV), dispersion (PWDisp), and terminal force in lead V1 (PTFV1) before and immediately after ablation. AF recurrence was assessed at 12 months. Analyses were adjusted for left atrial volume index (LAVI) and post-procedural anti-arrhythmic drug (AAD) use.
Results:
At 12 months, 215 patients (76%) remained free of AF (RF 76%, Cryo 74%, PFA 79%; p = 0.78). Baseline PWD was 128.5 ± 14 ms (RF), 123.7 ± 15 ms (Cryo), and 124.2 ± 16 ms (PFA). Post-ablation, mean ΔPWD was +12.2 ms (RF), +8.5 ms (Cryo), and + 4.7 ms (PFA). PTFV1 decreased after all modalities: RF -3.3 to -4.6 mm·ms (p < 0.001), Cryo -3.4 to -5.3 mm·ms (p = 0.002), PFA -3.6 to -5.2 mm·ms (p = 0.005). No significant intergroup differences were observed (p = 0.39). Patients with AF recurrence (n = 68) had longer baseline PWD (128 ± 16 vs. 125 ± 14 ms, p = 0.12), longer post-procedural PWD (138 ± 17 vs. 129 ± 15 ms, p = 0.004), and larger LAVI (29.1 ± 7.9 vs. 25.3 ± 8.5 mL/m2,p = 0.03). In multivariable Cox models, increased post-procedural PWD independently predicted recurrence (HR: RF 1.17, Cryo 1.14, PFA 1.13; all p < 0.05).
Conclusions:
PFA, RF, and Cryo produce similar acute ECG changes. Post-procedural PWD was the strongest predictor of AF recurrence, independent of atrial size and AAD use.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias